For exposure with lead screens, using either X-ray, gamma rays or radiation from megavolt equipment. For exposure with lead screens, using either X-ray, gamma rays or radiation from megavolt equipment Structurix D3 PB Vacupac 9cm x 12cm Structurix D3 FW 10cm x 24cm /li> /ul>D4 - Extra fine grain with very high contrast, Suitable for a wide variety of critical applications. This film obtains a very high detail perceptibility, which meets the requirements of the most critical NDT applications. I have no technical records or any specific documents on these films and I find few traces on the Internet.The following AGFA CONVENTIONAL RADIOGRAPHY FILM is stocked at our premises in Aberdeen- D3 - Ultra fine grain film with very high contrast. They are finished and I have to pronounce compliance but I do not have any documents on these films, just a very simple attestation written in Chinese speaking of a lot conformance to the norm.
AGFA STRUCTURIX D4 INDUSTRIAL X RAY SERIES
I would like to have the choice that you propose me and make the films with the series Structurix D but our subcontractor has already made all its films with the series Testix C4. My current problem concerns the Testix C series of films which, it seems, are made only for China. I am grateful for the time you would like to give to my question, and I thank you for your answer that will be useful to me today and in the future. Re: Difference between Agfa Structurix D7 and Agfa Testix D7 In Reply to Dr. Only for these film types ALL emulsions are evaluated and a complete film system survaillance is done by BAM Berlin as independent 3rd party, which is the pre-requisite for BAM film system certification!
AGFA STRUCTURIX D4 INDUSTRIAL X RAY ISO
So if you are working in the nuclear sector and want to prevent any surprise, than I recommend strongly to use ONLY Structurix D4 to D7 films, which are classified and certified to be in the correct film system classes according to ISO 11699 using standard NDT processing. And as expected, not all of these films are completely in the designated film system class C5, some are in film system class C6 according to ISO 11699-1! Since my last reply in 2015 some time passed by and we had the chance to test a few emulsions of Testix D7M films last year. Re: Difference between Agfa Structurix D7 and Agfa Testix D7 In Reply to Serge at 03:50 Dec-21-2017. The master rolls of both trade marks are manufactured with identical quality assurance by AGFA in Mortsel, Belgium.īut there are also TESTIX D7M, C7 and E7 films for the Asian NDT market, which do NOT correspond to STRUCTURIX films and does not fit into the ISO 11699-1 classification scheme.

This roll fulfills all requirements of the film system class C4 of ISO 11699-1, when developed under standard conditions of the AGFA chemisty, which can be proven by certified PMC strips purchased from AGFA.įor the films itself I do not see any difference between STRUCTURIX D5 or D7 films and TESTIX D5 and D7 films beside the packaging is done in different parts of this world. That it is within our product surveillance of STRUCTURIX NDT film batches with AGFA.

I am able to check the emulsion number of the master roll and can confirm, In India for local distribution under the brand name TESTIX.

purchased a master roll from AGFA Mortsel and cut and packed it I did not know this before, but all is clear now. Thank you very much for the image you posted. Re: Difference between Agfa Structurix D7 and Agfa Testix D7 In Reply to Shankar Arumugam at 14:09 May-29-2015. Director, BAM Berlin, Germany, Joined Jan 2010,